LED發(fā)光顏色 | Ultraviolet |
---|
峰值發(fā)光波長(cháng) | 365 nm typ. |
---|
外觀(guān)尺寸 | Outer diameter 100 mm, Inner diameter 43 mm, Height 35.5 mm |
---|
輸入電壓 | 24 VDC |
---|
消耗功率 | 18 W max. |
---|
極性, 信號 | 1: (24+), 2: NC, 3: GND(-), 4: NC |
---|
外殼材質(zhì) | Body: aluminum alloy (black anodized) Screws: SUS Washers: SUS, elastomer (TPE) Connectors: PA resin Lens: silicone |
---|
使用溫濕度 | Temperature: 0 to 40 ℃, Humidity: 20 % to 85 %RH (with no condensation) |
---|
保存溫濕度 | Temperature: -20 to 60 ℃, Humidity: 20 % to 85 %RH (with no condensation) |
---|
冷卻方式 | Natural air-cooling |
---|
輸入端口 | XS2M-D423 (Manufactured by OMRON) |
---|
適合規格 | CE, UKCA, RoHS, IEC 62471 (High risk), IP67 (JIS C 0920) |
---|
重量 | 420 g max. |
---|
附屬品 | User Manual, Radiation aperture seal, UV DANGER seal |
---|
注意事項 | * Do not expose your eyes or skin to direct UV irradiation. * When using an UV illumination, be sure to wear UV blocking eye wear and avoid looking at irradiating parts (emitting parts). * Do not turn on UV-LED irradiating parts (emitting parts) if they are facing someone's eyes. * Wear long sleeves and gloves to protect your skin from UV irradiation. * Thoroughly educate all those involved near the product about the dangers of UV LEDs. * After cleaning manufacturing lines, be sure to wipe away any moisture remaining on the lens. Imaging can be affected by moisture on the lens. * Use water to wash away any cleaning agent adhered to this product. * Use water to wash away any oils or chemicals adhered to this product. * The Control Unit connectors (SM connectors) on dedicated cables are not waterproof. |
---|
備注 | IP67 is the protection classification of an electric device against intrusion of foreign objects. -The first digit, 6, indicates the following protection level. Dust protected: Totally protected against dust. -The second digit, 7, indicates the following protection level. Immersion protected: Protected against short periods of immersion in water under defined conditions of pressure and time. If the height of the device is less than 850 mm, immersion at a depth of 1 m is allowed for a duration of 30 minutes. |
---|